sPHENIX Conference Note: BULK-2024-02

Title: Measurement of dET/dη with the sPHENIX detector using Run 2023 Au+Au data at 200 GeV
Date: 31 May 2024
Tag: sPH-CONF-BULK-2024-02
Document: Conference Note
(Back to sPHENIX Public Results page.)
Figure 1 (Click to download high-resolution PDF Figures.)
Mean correction factor value of reconstructed dET/dη for |η| < 0.5 divided by generator-level dET/dη, for sPHENIX calorimeter sub-systems as a function of centrality for range 0-60% centrality.
Figure 2 (Click to download high-resolution PDF Figures.)
Fully corrected dET/dη measurements over measurement range −1.1 < η < 1.1 for HCal-only results and −0.9 < η < 1.1 for EMCal-only and full calorimeter system results.
Figure 3 (Click to download high-resolution PDF Figures.)
Comparison of fully corrected dET/dη measurements for EMCal-only results (−0.9 < η < 1.1) and HCal-only results (−1.1 < η < 1.1).
Figure 4 (Click to download high-resolution PDF Figures.)
Comparison of fully corrected dET/dη measurements over measurement range −1.1 < η < 1.1 for HCal-only results and −0.9 < η < 1.1 for EMCal-only and full calorimeter system results.
Figure 5 (Click to download high-resolution PDF Figures.)
Fully corrected dET/dη measurements over measurement range −0.9 < η < 1.1 using the full sPHENIX calorimeter system. STAR and PHENIX measurements are included for comparison.